Best portable generators 2026: what size a house needs in a power cut, and how long 30 litres of petrol really lasts

A portable generator is not sized by adding up the labels. The running watts and the one motor that starts are two different numbers, and almost no listing says which of the two it is printing. On top of that sit three British constraints that decide the purchase before any model does: your network operator has 12 hours to restore supply in normal weather, you may keep only 30 litres of petrol at home without telling anyone, and the sound power level on the label is a ceiling the law sets rather than a warning. Here is the calculator, the census of what listings actually declare, and the eight models read against all of it.
This guide contains affiliate links. As an Amazon Associate, m8d.io earns from qualifying purchases, at no extra cost to you.

A portable generator is chosen on two figures, not one: the continuous power, which is what it will hold all night, and the maximum power, which is the one second in which a motor starts. On 6 September 2026 we counted 404 generator listings, and four of them print both figures. Before any of that, three British rules decide the shape of the purchase: the 12 hour restoration standard, the 30 litre petrol limit at home, and a legal ceiling on the sound power level.
Before the generator: what your network operator already owes you, and what you are actually buying cover for
In Great Britain a power cut is not an open ended event. If your supply fails in normal weather because of a fault on the distribution system, the network operator has 12 hours to restore it, and if it misses that, a payment is due to a domestic customer under Ofgem's guaranteed standards, with a further payment for each additional 12 hour period. In severe weather the clock and the amounts change with the storm category, and Ofgem re-sets the figures every April, which is why the number to look up is the current one on your own operator's page rather than one written in an article.
That changes what you are buying. A generator is not insurance against losing power: it is insurance against the first twelve hours, and against the storms where the twelve hour clock does not apply. Everything in this guide follows from that, because the honest question is not how many watts a house uses, it is how many hours you want to cover and where you can legally put the thing that covers them.
Three claims that come with this category, each set against what actually governs it here.
m8d rule: In normal weather your network operator has twelve hours to put the power back and owes you a payment if it does not. A domestic generator is cover for those twelve hours and for storms, so size it by the hours you want and by where it can stand, not by the biggest number on the box.
What size portable generator a house needs in a power cut, and why it is not the sum of the labels
A house that wants to keep the fridge, the freezer, the lights, the router and the television running asks for around 750 running watts. That is not the generator's figure. When the fridge compressor starts it asks for several times that for about a second, and that step is added once only, because the motors in a house do not start together. Two numbers come out, and both have to be checked.
The guides in this category all solve it the same way, with a percentage: add twenty or thirty per cent to the total. The same pages then explain, a few paragraphs down and without correcting the percentage, that a motor can ask for two to three times its rated power at the instant it starts, or that fridge and air conditioning motors have starting peaks three to five times their rated draw. Between thirty per cent and three hundred there is an order of magnitude, and it is exactly the one that decides whether the generator trips.
Generator sizing calculator: the running watts and the starting peak your house needs in a power cut
Free and no account. Tick what you want to keep running and the calculator returns both figures: the continuous watts and the starting peak, adding the step of one motor only, the largest. With the starting selection (fridge, freezer, lights, router and television) it comes to 750 running watts and a 1,150 watt peak, and the smallest generator in this guide that covers both is the K&S BASIC 20i S, with 1,800 watts rated and 2,000 maximum.
The arithmetic, in the open: 750 W running plus the step of the largest motor, which is 600 W less the 200 W it was already drawing, so 400 W more. Total: 1,150 W for one second and 750 W for the rest of the night. The factor of 3 times is the figure two of those tables agree on.

The running watts are the ranges published in the consumption tables this category puts out, read on 6 September 2026, and that is why the range and its source are shown rather than a single number: the three tables do not agree with each other. The starting factor is not agreed either, so the three that the category publishes are offered instead of one being imposed. There is no agreed starting factor, and that is the point: the consumption tables this category publishes give two, three and five times the running figure, so the calculator shows all three and says what each one is, instead of picking one and calling it the answer. The calculator applies no fuel price and no electricity price: everyone pays their own.
The practical consequence is that the appliance which decides the size of the generator is almost never the one that draws the most. A 2,000 watt heater has no motor: it asks for 2,000 watts and that is that. A 200 watt fridge asks for 600 for a second. And an 800 watt water pump, which is what sits in any house on a borehole, can ask for 2,400 at the start: on its own it doubles the generator that everything else needed.
- One figure, without saying whether it is the maximum or the rated onethe normal case24 listings73%
- Both power figuresK&S BASIC 20i S, KS 9200HDES, Briggs & Stratton P2400 and one other4 listings12%
- One figure, labelled as peak or maximumat least you know which one it is2 listings6%
- Not a single watt: only horsepower, kVA or nothingyou have to go to the manufacturer's spec sheet3 listings9%
m8d census of the 33 different fuel generator listings our Amazon API returned on 6 September 2026 across eight searches of the family. Among the 11 battery power stations in the same census, 5 of 11 write both figures. And across the 371 generator listings from the Leroy Merlin catalogue held in the m8d register, read on 1 September 2026, 73 titles use the word maximum, 7 use rated, continuous, permanent or prime, and none writes both.
Maximum power and rated power: which figure a generator listing is giving you when it gives only one
A petrol generator has two power figures because it has two limits: how much current it can give for a short while without the protection tripping, and how much it can give indefinitely without overheating. The second sits between 7 and 10 per cent below the first in the manufacturer spec sheets we read. The problem is not that the gap is large. It is that the listing does not say which of the two it is showing, and you do not have to leave one manufacturer's own catalogue to see it.
Könner & Söhnen publishes both power figures for every model in its BASIC range. Its three listings, read on 6 September 2026, pick three different conventions for the same piece of data, and none of them says which one it has picked.
“Inverter-Generator 2000 W… 1,8 kW Nennleistung”. Both figures, in German. Its spec sheet: 2.0 kW maximum and 1.8 kW rated. The listing matches.
“Petrol generator 3000 W”. One figure. Its spec sheet: 3.3 kW maximum and 3.0 kW rated. The listing is giving the rated figure, the small one.
“Inverter generator 3.8 kW”. One figure. Its spec sheet: 3.8 kW maximum and 3.5 kW rated. This listing is giving the maximum, the big one.
Same manufacturer, same range, same shop and the same day: one gives both, one gives the small figure and one gives the big one. The gap between the two is 10 % on the 20i S, 9.1 % on the 33i S and 7.9 % on the 38i. On the same brand's diesel set the gap is wider, because the voltage changes too: its spec sheet publishes 7.5 and 7.0 kW at 400 volts and 6.5 and 6.0 kW at 230, while its listing is titled 7500/6400 W. A British house on single phase uses the 6,000.
m8d rule: If a generator gives one watts figure, take 10 per cent off it before comparing it with what you need. And if it has a 400 volt output, find the 230 volt continuous row in the manufacturer's spec sheet: the big number in the title is the three phase one.
Read the eight against both figures at once, with the fuel and the sound power beside them, and the list sorts itself into three groups: the ones you can carry, the ones you install, and the one that does not burn anything.
| Model | Rated | Maximum | Declared noise | Fuel, and the 30 litre rule | Who it is for | |
|---|---|---|---|---|---|---|
| 3,000 W | 3,300 W | 68 dB at 7 m · 95 Lwa | Petrol: 30 litres is about 44 hours at half load | A whole house | View › | |
| 6,000 W at 230 V | 6,500 W at 230 V | 69 dB at 7 m · 94 Lwa | Diesel: the petrol limit does not catch it | A large house, or one on a borehole | View › | |
| 1,800 W | 2,400 W | 58 dB at 7 m at 25 % load | Petrol, and it is the quietest documented here | The basics, close to the house | View › | |
| 1,800 W | 2,000 W | 70 dB at 7 m · 95 Lwa | Petrol, 4 litre tank: seven refills to use the 30 | Fridge, lights and broadband | View › | |
| Not published | 6,500 W declared | Not published | Diesel, with transfer gear included | Automatic starting, cheaply | View › | |
| Not published | 7,500 W declared | Not published | Petrol or bottled gas, which sidesteps the limit | A workshop and machinery | View › | |
| 2,400 W | 4,800 W | No engine | None: it is the only one allowed indoors | A flat, with no fumes | View › | |
| Not published | 2,300 W peak | Not published | Petrol, and it does not publish its tank | A campervan | View › |
The power figures and the decibels come from each manufacturer's spec sheet, read on 6 September 2026, and not from the shop listing. Where it says not published, it is the manufacturer that does not publish that figure, not the machine that lacks it. Könner & Söhnen declares its decibels as Lpa at seven metres and as Lwa; Briggs & Stratton declares its at a quarter load, at seven metres and from the control panel side. The fuel column applies the 30 litre limit of the Petroleum (Consolidation) Regulations 2014 to the autonomy each manufacturer declares: 30 litres is seven and a half tank fulls of the 33i S at 4 litres, and its declared 5.9 hours at half load make about 44 hours in all.
The 30 litres of petrol you may keep at home, and how many hours of generator that actually is
Every listing in this category sells autonomy by the tank, and in Britain the tank is not the constraint. Under the Petroleum (Consolidation) Regulations 2014 you may keep up to 30 litres of petrol at a private home without notifying your local petroleum enforcement authority, in containers of up to 10 litres in plastic, up to 20 in metal, or a demountable fuel tank of up to 30. Above 30 and up to 275 litres you have to notify them in writing. The store must not be in living accommodation, and if it is not in the open air it needs a direct exit to outside and ventilation to it.
Apply that ceiling to the figures the manufacturers publish and the autonomy question answers itself. The 3 kW inverter here declares 5.9 hours at half load on a 4 litre tank, so the full legal store is seven and a half tanks and about 44 hours. That is comfortably past the 12 hour standard and into a serious storm. And the ceiling is a petrol ceiling: those regulations are about petrol, so the diesel set in this guide is not caught by them, which is the single biggest practical difference between the two fuels here and it appears in no listing.
The pump price is the one figure here that nobody should read in an article: the Department for Energy Security and Net Zero publishes average unleaded and diesel prices every week, and the latest release at the time of writing covered the week beginning 14 September 2026. Multiply your own pence per litre by the 0.45 or the 0.60 above and the running cost is yours rather than ours.
The 95 dB on a generator label is a legal ceiling, not a warning: what the two decibel figures mean
Of the 33 fuel generator listings we counted on 6 September 2026, seven call themselves silent or soundproofed and none publishes a decibel. Across the 371 in the Leroy Merlin catalogue, 16 titles carry a decibel figure. The figure always exists, and not because the manufacturer is generous: because a law requires it to be on the machine, and in Great Britain that same law also caps it.
When a spec sheet publishes “68/95 dB” it is not giving a range. It is giving two different quantities, and only one of them resembles what the neighbours will hear.
“Silent generator”, with no figure at all. That is what all seven listings in the census that use the word do, including a soundproofed diesel set sold as a quiet single phase machine.
This is the one that resembles what you hear, and it only means something with its distance beside it. Könner & Söhnen publishes it as Lpa (7): 68 dB at seven metres on the BASIC 33i S. Briggs & Stratton goes further and declares all three conditions: 58 dB at a quarter load, at seven metres and from the control panel side.
This is Lwa, 95 dB on that same BASIC 33i S, and it is not what you hear: it is the acoustic energy the machine emits, independent of distance. It is there by law. Regulation 11 of the Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001 requires that “the CE marking and the indication of the guaranteed sound power level shall be affixed in a visible, legible and indelible form to each item of equipment”.
In those same regulations, power generators of 400 kW and above sit in Schedule 2, the marking only list. Power generators below 400 kW, which is every machine in this guide, sit in Schedule 1, the list subject to noise limits, and Schedule 3 sets the permissible sound power level by formula on the electric power P: for the Stage II figures, 95 + lg P up to 2 kW, 96 + lg P from 2 to 10 kW and 95 + lg P above 10. For a 1.8 kW machine that works out at 95.3 dB and for a 3 kW one at 96.5: the labels here are sitting at or just under their own ceiling.
m8d rule: The guaranteed sound power level of a generator is always written, because the law makes the manufacturer mark it on the machine, and for a machine under 400 kW the law also caps it by a formula on its electric power. So a 95 dB label on a small generator is not a bad sign: it is the ceiling. The figure that tells you what you will hear is the other one, the small one, and only with its distance written beside it.
Two figures can only be compared if they are measured the same way, and if one spec sheet says 58 and another says 95, the likely explanation is not that one machine is far quieter: it is that they are giving different quantities. If it is going near the house, the one that matters is the small one, with its distance and its load written beside it. Outdoors, a sound source gains roughly six decibels every time you halve the distance, so 58 dB at seven metres is not the 58 dB you will hear from the window.
We would not buy a generator that calls itself silent and prints no figure, and the reason is not scepticism: the guaranteed sound power level has to be marked on the machine by law, so a listing without it is a listing that did not copy what is already stamped on the casing.
Inverter or conventional: what changes for the fridge, for the boiler and for the laptop
A conventional generator takes its current straight off the alternator, so its frequency rises and falls with the engine speed. An inverter rectifies it and rebuilds it electronically, which is why it is advertised as a pure sine wave. For a bulb or a heating element it makes no difference. For the control board of a modern boiler, a router or a laptop it does: those are the things that cope worst with a frequency that wanders.
There is a second effect, and it shows up more in the noise than in the fuel: not having to spin at a fixed 3,000 revolutions to make 50 hertz, an inverter drops the engine when the house is asking for little. That is why the K&S BASIC 33i S declares 68 dB at seven metres with 3 kW rated and its 1.8 kW sibling declares 70.

Könner & Söhnen BASIC 33i S view ›
It covers a real house, fridge, freezer, boiler, lights and broadband, with room for the largest motor's starting step, and it is one of the few whose manufacturer publishes both power figures and both decibel figures. Its listing is also titled with the small figure, which is the honest one.
- Its manufacturer publishes the four figures you need to decide: 3.3 kW maximum, 3.0 kW rated, 68 dB of sound pressure measured at seven metres and 95 dB of sound power (Könner & Söhnen spec sheet, read on 6 September 2026).
- Its listing is titled with the small figure, the 3,000 rated watts, which is the one that holds all night. Of the 33 fuel generator listings we counted that day, 24 give a single figure without saying which of the two it is.
- That 95 dB sound power figure is not a black mark: for a 3 kW machine the ceiling in Schedule 3 of the outdoor noise regulations works out at 96.5 dB on the Stage II formula, so it is publishing a figure that sits just under its own legal limit.
- A 4 litre tank and 5.9 hours at 50 % load, per its spec sheet. At 50 % of 3.0 kW that is 1.5 kW for 5.9 hours on 4 litres: 0.45 litres of petrol per kilowatt hour. The 30 litres you may keep at home is seven and a half of those tanks, or about 44 hours.
- 3,000 rated watts and 3,300 maximum published by the manufacturer, not inferred
- 68 dB at seven metres, among the lowest at its output
- Euro 5 engine and a brushless alternator with copper windings, per its spec sheet
- 21.5 kg net: two people move it without a trolley
- A 4 litre tank means seven refills to work through the 30 litres you are allowed to keep
- No electric start and no automatic transfer: it is started by hand
- It is petrol, so it goes outside and away from a window, never in the garage

Briggs & Stratton P2400 PowerSmart view ›
It documents its noise better than anything else here: 58 dB with all three conditions written down, at a quarter load, at seven metres and from the control panel side. And its listing carries both power figures, which only four of the thirty three do.
- Its listing writes both power figures, 2,400 and 1,800 W, which is what four of the thirty three fuel generator listings we counted do. And its manufacturer's spec sheet says which is which: 2,400 W starting and 1,800 W continuous.
- Its spec sheet does not publish a bare decibel: it publishes 58 dB with the conditions beside it, measured at a quarter load, at seven metres and from the control panel side. A noise figure without those three conditions cannot be compared with this one.
- 1,800 continuous watts are enough for fridge, freezer, lights, broadband and television with one household motor's starting step inside, but they run out the moment an electric heater or a microwave joins in.
- A 79 cc four stroke OHV engine, 22.7 kg, and up to 8 hours at a quarter load, per the manufacturer spec sheet read on 6 September 2026.
- Both power figures in the listing itself, and a spec sheet that says which is which
- 58 dB with distance, load and side declared: it can actually be compared
- 22.7 kg, one person lifts it
- Inverter waveform, meant for appliances with electronics in them
- 1,800 continuous watts will not run electric heating, or the microwave and the fridge together
- It costs noticeably more than inverters here with a higher rated output
- No electric start: it is started by pulling the cord
Petrol, diesel or battery: where you are allowed to put it, and what has to happen before it feeds the house
Two questions decide this, and neither is price. The first is where it will stand: anything that burns fuel produces carbon monoxide, so it goes outside, in the open air and away from doors and windows, never in a garage and never in an enclosed porch. In a flat that condition cannot be met, and the answer is a battery.
The second is what it is feeding. Running extension leads to a fridge, a lamp and a router is one thing. Feeding the fixed circuits of the house is another: it needs an isolating changeover arrangement fitted by an electrician, so that the generator and the incoming mains can never be live at the same time. Two of the eight here include that transfer gear, and it is most of what separates their price from the rest.
Then it is hours. A battery station has no awkward power limit, but it has an energy limit: 2,048 watt hours run out. A petrol machine does not run out while there is fuel in the store, which in Britain is 30 litres, and diesel is not caught by that ceiling at all. Our split would be battery for a flat and for a cut measured in hours, a petrol inverter for a house, and diesel for a large house or one on a borehole pump.

FOSSiBOT F2400 view ›
The answer for a flat, where a fuel generator cannot be kept at all. It burns nothing, switches over in under eight milliseconds and gives both power figures in its own title. The trade off is hours, not watts.
- It writes both power figures in its title, 2,400 continuous watts and 4,800 peak, which is what 5 of the 11 battery stations we counted do and only 4 of the 33 fuel generators.
- It switches over in under 8 milliseconds, per its manufacturer, so the computer, the router and the boiler never notice the cut. A generating set with automatic transfer takes seconds, not milliseconds.
- 2,048 watt hours is energy, not power. Against the 750 W of the default selection in the calculator on this page, the division gives about two and a half hours. A petrol machine with cans does not have that ceiling, although in Britain its cans do.
- It burns nothing, so it can be inside the dwelling. In a flat, where a fuel generator cannot legally or safely stand anywhere, it is the only form of backup there is.
- A LiFePO4 battery rated at more than 3,500 charge cycles by the manufacturer: it is the chemistry that tolerates standby use, where the machine spends months charged and doing nothing.
- It can be kept indoors: no fumes and no carbon monoxide
- Both power figures written in the listing, 2,400 and 4,800 W
- Switchover in under 8 ms: it works as an uninterruptible power supply
- Silent, with no engine starting at three in the morning
- 2,048 Wh is about two and a half hours at 750 W: short for a cut that lasts a day
- It recharges from the mains, and in a long cut there are no mains to recharge it from
- It costs about the same as a petrol generator with considerably more power and hours

Könner & Söhnen KS 9200HDES-1/3 ATSR view ›
The only one here that brings the power back without anyone stepping outside: its transfer unit starts the engine when the mains fail and stops it when they return. Its spec sheet publishes four power figures, and the one a British house uses is the 230 volt continuous row.
- Its spec sheet publishes four power figures: 6.5 and 6.0 kW (maximum and rated) at 230 volts, and 7.5 and 7.0 kW at 400. Its listing is titled 7500/6400 W. A British house runs single phase at 230 volts, so the figure that is actually useful is 6,000 continuous watts, fifteen hundred less than the headline.
- The manufacturer declares Lpa 69 dB at seven metres and Lwa 94 dB. Those are not two machines: the first is what you hear at seven metres and the second is the guaranteed sound power level that the outdoor noise regulations require to be marked on the machine, and which for a 6 kW set the Stage II formula caps just under 97 dB.
- The ATS unit is what separates it from the rest. The manufacturer describes it exactly: it starts the generator and transfers the load when the mains fail, and stops it when supply is restored. It is also the part that needs an electrician, because transferring the load means isolating from the incoming supply.
- A 20 litre tank and 11.1 hours at 50 % load: 3 kW for 11.1 hours on 20 litres is 0.60 litres of diesel per kilowatt hour. And it is diesel, so the 30 litre petrol ceiling at home does not apply to it, which for a long storm is worth more than the extra kilowatts.
- 168 kg net. This is not stored in a shed and wheeled out when needed: it is installed somewhere and it stays there.
- Starts and stops on its own with the ATS unit, without anyone going outside
- 6,000 rated watts at 230 V published by the manufacturer, with its 400 V row separate
- 11.1 hours at 50 % load on 20 litres of diesel, and no 30 litre storage ceiling
- Preheater for cold starting, per its spec sheet, and a Euro V engine
- 168 kg: it needs a fixed, ventilated place outside the dwelling
- Its title advertises 7,500 W, which is the 400 V output that a normal house does not have
- A 498 cc diesel needs engine maintenance: it is not a plug in and forget appliance
- The transfer gear has to be wired in by an electrician, and that is part of the real cost

For anyone who only wants the food not to spoil and the lights and broadband to stay on. It covers the calculator's default selection with margin, and its listing writes the rated power, which almost nothing in this price band does.
View ›
It does one thing the rest of its price band does not: it says which of the two power figures it is printing. What it does not publish is the rated one, and without that there is nothing to compare against the arithmetic of a household power cut.
View ›
Automatic transfer for less money. In exchange its spec sheet has to be rebuilt: the title mixes electrical watts with engine kilowatts and does not say which of the two power figures it is advertising.
View ›
For a workshop or a house with machinery: two fuels and a three phase output. Watch its headline figure, which is the three phases together and not what will reach a socket in the house.
View ›Which of the eight to buy, according to what you want to keep running
Four cases cover almost everyone who arrives on this page. Pick yours and the model appears, with the reason in one line.

1,800 rated watts published by the manufacturer cover the 750 W of that house with one motor's step inside it, and at 18 kg it is the lightest here.
See it on Amazon ›How these eight generators were chosen, and where every figure on this page comes from
We started from the catalogue, not from a list. On 6 September 2026 we ran eight searches of this family through our Amazon API and gathered 44 different listings: 33 fuel generators and 11 battery power stations. The same day we read the Leroy Merlin catalogue held in the m8d register, itself read on 1 September 2026, and counted 371 more generator listings. Across those 404 titles we counted which power figure each one declares, which is the count that opens this guide.
Then we went to the source of every number. The power figures, the decibels, the engine capacity, the tank and the autonomy of the selected models come from each manufacturer's own spec sheet, not from the shop listing, and carry their date of reading. The British rules are read at source on legislation.gov.uk and on GOV.UK: the Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001 for the sound power marking and its ceiling, and the Petroleum (Consolidation) Regulations 2014 for how much petrol may be kept at a home. The restoration standard and the payments come from Ofgem. The appliance consumption ranges are the ones the category's own tables publish, which is why the calculator shows the range and who publishes it rather than a number with no owner: the three tables do not agree with each other.
Five criteria order the selection and none decides alone: that the manufacturer publishes the rated power and not only the maximum, that it publishes the noise with its measurement conditions, the real autonomy with the tank it actually has, whether starting is manual, electric or automatic, and where the machine is allowed to stand. A product without a fresh price and stock reading does not get in, and none of the eight was chosen for having an affiliate programme.
Availability and model ranges vary by country: the buttons take you to your local Amazon store so you can check yours, and the rules quoted here are the ones that apply in Great Britain.
What size generator do I need to run a house in a power cut?›
Not the sum of the labels. A house keeping the fridge, the freezer, the lights, the router and the television running comes to about 750 running watts, and the starting peak adds the surge of one motor only, the largest, because the motors in a house do not start together. With the fridge at 200 watts and a factor of three, that peak is about 1,150 watts, not the 940 that a twenty five per cent margin would give. The calculator on this page does both figures and names the smallest machine here that covers them.
How much petrol can I legally store at home in the UK?›
Up to 30 litres at a private home without notifying your local petroleum enforcement authority, under the Petroleum (Consolidation) Regulations 2014, in containers of up to 10 litres in plastic, up to 20 litres in metal, or a demountable fuel tank of up to 30 litres. Between 30 and 275 litres you must notify them in writing. It must not be stored in living accommodation, and if the store is not in the open air it needs a direct exit to outside and ventilation to it. Those regulations are about petrol, so a diesel generator is not caught by that ceiling.
How long will a portable generator run for?›
On the declared figures here, the 3 kW petrol inverter gives 5.9 hours at half load on a 4 litre tank and the 6 kW diesel set gives 11.1 hours at half load on 20 litres. The number that matters in Britain is what the legal store adds to that: 30 litres of petrol is seven and a half tanks of the small one, so about 44 hours. A battery station is a different shape of answer, 2,048 watt hours, which is roughly two and a half hours at 750 watts and cannot be topped up while the power is off.
Can I plug a generator into my house wiring?›
Not directly. Feeding the fixed circuits of a house needs an isolating changeover arrangement installed by an electrician, so that the generator and the incoming mains can never be live at the same time. Running extension leads from the machine to individual appliances is a different job and is what most portable generators are bought for. Two of the eight here include automatic transfer gear, which is the hardware that does the switching, and that is most of what separates their price from the rest.
What does the 95 dB on a generator label mean?›
It is the guaranteed sound power level, which is the acoustic energy the machine emits regardless of distance, and it is on the machine because regulation 11 of the Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001 requires the CE marking and that figure to be affixed in a visible, legible and indelible form. It is also capped: power generators below 400 kW sit in Schedule 1 of those regulations, the list subject to noise limits, and the permissible level is set by a formula on the electric power. The figure that tells you what you will hear is the other one, the sound pressure, and only with its distance beside it.
Do I get compensation if my power is cut off?›
In normal weather your network operator has 12 hours from becoming aware of a fault to restore supply, and Ofgem's guaranteed standards provide for a payment to a domestic customer if it does not, with a further payment for each additional 12 hour period. Severe weather has its own arrangements, with the amount depending on the storm category. The amounts are re-set every April, so the figure to rely on is the current one published by Ofgem and by your own network operator, which is also who pays it.
Is an inverter generator worth the extra?›
It depends entirely on what you are plugging in. A conventional generator's frequency moves with the engine speed, which a bulb or a heating element does not care about and a boiler control board, a router or a laptop does. The second reason is noise: an inverter can drop the engine speed when the house is asking for little, which is why the 3 kW inverter here declares 68 dB at seven metres while its 1.8 kW sibling declares 70.
Every figure on this page comes from one of these, with the exact section and the date it was read.
- legislation.gov.ukThe Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001, regulation 11“The CE marking and the indication of the guaranteed sound power level shall be affixed in a visible, legible and indelible form to each item of equipment.” Read on 16 September 2026
- legislation.gov.ukThe same regulations, Schedule 1 and Schedule 2Schedule 1, the equipment subject to noise limits, lists power generators below 400 kW. Schedule 2, the equipment subject to noise marking only, lists power generators of 400 kW and above. Read on 16 September 2026
- legislation.gov.ukThe same regulations, Schedule 3: permissible sound power levelsFor power generators the parameter is the electric power P in kW. Stage I, from 3 January 2002: 97 + lg P up to 2 kW, 98 + lg P from 2 to 10 kW and 97 + lg P above 10. Stage II, from 3 January 2006: 95 + lg P, 96 + lg P and 95 + lg P, with a note that the Stage II figures are indicative pending amendment. Read on 16 September 2026
- Dorset and Wiltshire Fire and Rescue ServiceSafe storage of petrol, under the Petroleum (Consolidation) Regulations 2014Up to 30 litres of petrol may be kept at a home without informing the local petroleum enforcement authority; plastic containers up to 10 litres, metal up to 20, demountable fuel tank up to 30; between 30 and 275 litres the authority must be notified in writing. Read on 16 September 2026
- OfgemCompensation for energy supply issues, and the guaranteed standards of performanceOfgem sets the guaranteed standards of performance payment amounts for each regulatory year, adjusted annually. In normal weather the network operator has 12 hours to restore supply and a payment is due to a domestic customer if it does not, with a further payment for each additional 12 hour period; severe weather has its own arrangements by storm category. Read on 16 September 2026
- Department for Energy Security and Net ZeroWeekly road fuel pricesWeekly average pump prices for unleaded petrol and diesel. Latest release at the time of writing: 15 September 2026, for the week commencing 14 September 2026. Used here as the place to get your own pence per litre, not quoted as a figure. Read on 16 September 2026
- m8d.iom8d census of the generator catalogue44 different listings read through our Amazon API in eight searches on 6 September 2026 (33 fuel generators and 11 battery power stations), plus 371 generator listings from the Leroy Merlin catalogue in the m8d register, read on 1 September 2026. Of the 33 fuel listings: 24 give one power figure without saying which, 4 give both, 2 label theirs as peak or maximum and 3 give no watts at all
- Könner & Söhnen, Briggs & Stratton, T-Mech, Extralink, FOSSiBOT and maXpeedingrodsManufacturer spec sheets for the eight selected modelsSource of every power figure, decibel, engine capacity, tank size and declared autonomy in this guide, read on 6 September 2026. Where a figure is marked as not published, it is the manufacturer that does not publish it
For a house, the K&S BASIC 33i S: 3,000 rated watts and 3,300 maximum, both published by the manufacturer, 68 dB at seven metres, and a 4 litre tank that the legal 30 litre store turns into about 44 hours. For a flat, where nothing may burn, the FOSSiBOT F2400, which switches over in under eight milliseconds and can stand indoors, at the cost of hours rather than watts. And if the point is that the power comes back without anyone going outside at three in the morning, the KS 9200HDES, with its transfer unit and a fuel the 30 litre rule does not reach.
One thing above all three. The advertising in this category is about watts, and in Britain the purchase is decided by hours and by where the machine can legally stand. Your network operator owes you after twelve hours, you may keep thirty litres of petrol at home, and a machine that feeds the fixed wiring needs an electrician either way. We would settle those three before comparing a single specification, because they decide which of these eight is even eligible.
Best log burnersThe heat that keeps working when the electricity does not: what size, what you may burn, and how much wood a winter takes
Best burglar alarms with no monthly feeWhich alarms carry their own battery and a backup SIM, and survive the cut that takes the broadband with it
Best outdoor security camerasThe ones that record to a local card, which is the only kind that still works when the router is deadComments
Be the firstNo sign-up: just a name. Every comment is reviewed before it is published.